Pure Sine Inverter With Charger

4000W DC 48V Split Phase Pure Sine Wave Inverter With Charger

Hightlight:

  • ★ This LFP Series Pure Sine Wave Inverter is a combination of an inverter, battery charger and AC auto-transfer switch. low frequency, low Idle Current, BTS cable, remote control.

  • ★ AC/Battery Priority: Our inverter is designed with AC priority by default, you can choose the battery priority by SW5 switch.

  • ★ Adjustable Charging Current: The max charge current can be adjusted from 0%-100% via a liner switch. 

  • ★ Auto Gen Start: The inverter can start up a generator when battery voltage goes low. and turn the generator off after battery charging is finished.


QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question

Features

Main Features:

  • 4000W Low Frequency Pure Sine Inverter With Charger.
  • AC/Battery Priority Selector.
  • Automatically Generator Start.
  • Safety and Convenient.
  • The low freqency inverter can power all kinds of appliances.
  • LCD Display, Remote Control.
  • Low Idle Consumption.
  • 7 battery type settings for charger.
  • Multi Stage Smart charger 40+/-5A, charger can be disable.
  • 10msec typical transfer time.

Packaging:

  • 4000W 48V Low Frequency Pure Sine Inverter
  • English Manual
  • Remote Control
  • BTS Cable
  • Unit Weight: 53LB 
  • Unit Size: 17.4 x 9.5 x 7.8 inch
  • Shipping Weight: 57LB 
  • Shipping Size: 23 x 12.6 x 12.0 inch

4000W 48V SPLIT Pure Sine Wave Inverter

Specification

Main Specification:

Inverter Output:

  • Continuous Output Power: 4000W 
  • Surge Rating: 12000W (20 Seconds)
  • Output: AC120V and AC 240V ,60HZ
  • AC Input:240V
  • Output Wave: Pure Sine Wave (bypass mode)
  • Typical Transfer Time: 10ms (MAX)
  • Nominal Efficiency: >88%

DC Input:

  • Nominal Input Voltage: 48.0Vdc
  • Minimum Start Voltage: 40.0Vdc
  • Low Battery Alarm: 42.0Vdc-44.0Vdc
  • Low battery Trip: 40.0Vdc-42.0Vdc (select by SW1)
  • High Voltage Alarm: 64.0Vdc
  • Low battery Voltage Restart: 52Vdc
  • Idle Consumption: 48W 
  • Power Saver Mode Idle Consumption: 19W

AC Charger :

  • Charger Rate: 40+/-5A
  • AC input Range (Grid or Generator): 90V-135VAC/100V-135VAC (select by SW2), 140V-270VAC/184V-253VAC (select by SW2)
  • Over Charge Protection Shutdown:62.8V
  • Selectable Charge Setting based on battery type
  • Adjustable charge current: off 0%-100%
  • 3-step intelligent battery charger
    User Manual


    Download LFP Series Pure Sine Wave Inverter/Charger User's Manual

    FAQ

    Frequently Questions Answer

    1. What's the AC output amps?

        Dear Customer, output amps is 16A, load can't exceed 4000W when 240V AC load, load can't exceed 2000W when 120V AC load, because this is split phase inverter, the power will be divided to 2*2000W when 120V output, hope your kind understanding, thanks.

    2. What is the maximum charging voltage for this Inverter?

        Dear Customer, it will have over charge protection shutdown if it exceeds 62.8V, thanks.

    3. Can it charge 7 modules of Nissan leaf battery? (56 volts 66ah) (1 module: 8v 66ah)?

        Dear Customer, you could find the battery type selector in manual, you need to choose different switch position according to your battery voltage, please download manual from Technical specification of product page, in addition, the battery total voltage can't exceed 48V, thanks.